Improvements on a Numerical Model of Borehole Heat Exchangers [Elektronisk resurs]

Puttige, Anjan Rao (författare)
European Geothermal Congress 
Rodriguez, Juan (författare)
Monzó, Patricia (författare)
Cerdeira, Fernando (författare)
Fernández, Alfredo (författare)
Novelle, Lucia (författare)
KTH Skolan för industriell teknik och management (ITM) (utgivare)
Publicerad: 2016
Engelska.
Ingår i: Proceedins of the European Geothermal Congress 2016.
Läs hela texten
Läs hela texten
Läs hela texten
  • E-bok
Sammanfattning Ämnesord
Stäng  
  • In the mathematical simulation of bore fields for ground coupled heat pump (GCHP) systems, it has become a common practice to consider the boreholes as having a uniform temperature. As a rule the boreholes are hydraulically connected in parallel and the small temperature difference between incoming and outgoing heat carrier fluid justifies the assumption that all boreholes have the same uniform temperature in operation. Two simultaneous boundary conditions usually apply: All borehole walls should have a uniform temperature and the heat flow from the bore field should equal the energy needed by the heat pump. This paper describes improvements applied to a previous numerical approach that employs the concept of a highly conductive material (HCM) embedded in the boreholes and connected to a HCM bar above the ground surface to impose a uniform temperature boundary condition at the borehole wall. The original boundary condition with the uniform fluid temperature comes in conflict with the concept of the uniform borehole wall temperature. Between the fluid and the borehole wall there is a thermal borehole resistance. The heat flux increases at the borehole ends and thus also the temperature changes between borehole wall and the fluid. The borehole wall temperature deviates from the uniform assumption and will cause an error in the simulations. This paper presents a correction to that error. Firstly, the improvements to the HCM model are validated for g-function generation, which presents a good agreement with reference solutions. Secondly, the improvements to the HCM model are illustrated to predict fluid temperatures for measured variable daily loads of a monitored GCHP installation. The predicted fluid temperatures are compared with monitored data for about four years. The predicted fluid temperatures deviate from the measured data by less than 1 K during the last monitored year.  

Ämnesord

Engineering and Technology  (hsv)
Mechanical Engineering  (hsv)
Energy Engineering  (hsv)
Teknik och teknologier  (hsv)
Maskinteknik  (hsv)
Energiteknik  (hsv)

Indexterm och SAB-rubrik

Monitored installation
borehole heat exchanger
fluid temperature prediction
Inställningar Hjälp

Uppgift om bibliotek saknas i LIBRIS

Kontakta ditt bibliotek, eller sök utanför LIBRIS. Se högermenyn.

Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy