Startsida
Hjälp
Sök i LIBRIS databas

     

 

Sökning: onr:6plzgjfw45rf5rzm > Determination of th...

Determination of the Plasma Delay Time in PIPS detectors for fission fragments at the LOHENGRIN spectrometer [Elektronisk resurs]

Gomez L, Ana Maria, 1993- (författare)
15th International Conference on Nuclear Data for Science and Technology (ND2022) 
Al-Adili, Ali (författare)
Göök, Alf (författare)
Pomp, Stephan, 1968- (författare)
Pousette, André (författare)
Solders, Andreas, 1976- (författare)
Tarrío, Diego (författare)
Gao, Zhihao (författare)
Köster, Ulli (författare)
Kim, Yung Hee (författare)
Smith, A. Gavin (författare)
Sosnin, Nikolay V. (författare)
Bennett, Samuel (författare)
Wright, Tobias (författare)
Oberstedt, Andreas (författare)
Oberstedt, Stephan (författare)
Uppsala universitet Teknisk-naturvetenskapliga vetenskapsområdet (utgivare)
Uppsala universitet Teknisk-naturvetenskapliga vetenskapsområdet (utgivare)
Publicerad: EDP Sciences, 2023
Engelska.
Ingår i: 15<sup>th</sup> International Conference on Nuclear Data for Science and Technology (ND2022).
Läs hela texten
Läs hela texten
Läs hela texten
  • E-bok
Sammanfattning Ämnesord
Stäng  
  • The VElocity foR Direct particle Identification spectrometer (VERDI) is a 2E-2v fission spectrometer that allows the measurement of the total mass distribution of secondary fission fragments with a resolving power of 1-2 u. It consists of two time-of-flight (ToF) arms, with one Micro Channel Plate (MCP) detector and up to 32 Silicon PIPS (Passive Implanted Planar Silicon) detectors per arm. The MCPs provide the start timing signals and the PIPS detectors provide both the energy and the stopping ToF signals. In real conditions, the PIPS signals are affected by the formation of plasma from the interaction between the heavy ions and the detector material. The plasma contributes to a reduction in signal amplitude, resulting in a Pulse Height Defect (PHD), and introduces a signal delay, known as Plasma Delay Time (PDT). An experiment to characterize the PDT and PHD was performed at the LOHENGRIN recoil separator of the Institut Laue Langevin (ILL). Characteristic fission fragments from the 239Pu(n,f) reaction were separated based on their A/Q and E/Q ratios, allowing the measurement of a wide range of energies from 21 to 110 MeV and masses between 80 and 149 u. Six PIPS detectors were characterized to study their individual responses to the PDT and PHD effects. The signals were recorded in a digital acquisition system to completely exploit the offline analysis capabilities. Achieved combined timing and energy resolutions for fission fragments varied between 72(2) ps and 100(4) ps and 1.4% - 2% (FWHM), respectively. Preliminary PHD and PDT data are presented from the masses A=85, 95, 130 and 143. The PHD trends are strongly correlated with both the ion energy and mass. The PDT, on the other hand, shows a strong variation as a function of the ion kinetic energy but a smaller dependence on the ion mass. 

Ämnesord

Natural Sciences  (hsv)
Physical Sciences  (hsv)
Subatomic Physics  (hsv)
Naturvetenskap  (hsv)
Fysik  (hsv)
Subatomär fysik  (hsv)
Fysik med inriktning mot tillämpad kärnfysik  (uu)
Physics with specialization in Applied Nuclear Physics  (uu)

Genre

government publication  (marcgt)
Inställningar Hjälp

Uppgift om bibliotek saknas i LIBRIS

Kontakta ditt bibliotek, eller sök utanför LIBRIS. Se högermenyn.

Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy